XM-LFAG is a B Series straight male connector designed for installation through an equipment panel. Its threaded mounting body, retaining nut and alignment feature provide secure mechanical installation and help prevent rotation after mounting.
Unlike conventional Push-Pull self-latching connectors, this model is specified without a locking mechanism. The connector can therefore be mated and removed directly without releasing a latch, making it suitable for applications requiring quick connection and frequent disconnection.
A standard G alignment key ensures correct connector orientation. Optional A–M key configurations are available to help prevent cross-mating between similar connectors installed in the same system.
Product Features
- Straight male panel receptacle
- Non-locking mating interface
- Threaded body with nut-mounted panel retention
- Alignment feature for accurate installation
- Standard G key for correct mating orientation
- Optional A–M key configurations
- Quick connection and removal without operating a latch
- Available in shell sizes from 00B to 4B
- Compact metal construction
- Suitable for frequently connected equipment interfaces

Dimensions
All dimensions are in millimetres.
| Shell Size | A | B | Mounting Thread M | L1 | L2 | L3 | L4 | SW1 | SW3 |
|---|---|---|---|---|---|---|---|---|---|
| 00B | 8 | 10.2 | M7 × 0.5 | 18.1 | 15.0 | 2.9 | 9.0 | 6.3 | 9 |
| 0B | 10 | 12.4 | M9 × 0.6 | 20.8 | 18.4 | 4 | 11.2 | 8.2 | 11 |
| 1B | 14 | 15.8 | M12 × 1.0 | 25.2 | 22.6 | 5 | 12.5 | 10.5 | 14 |
| 2B | 18 | 19.2 | M15 × 1.0 | 28.7 | 23.9 | 6 | 13.8 | 13.5 | 17 |
| 3B | 21 | 25 | M18 × 1.0 | 32 | 29.1 | 6 | 17 | 16.5 | 22 |
| 4B | 29 | 34 | M25 × 1.0 | 37 | 34 | 7 | 20.5 | 23.5 | 30 |
Recommended Panel Cutout
| Shell Size | Flat Width SW | Cutout Diameter |
|---|---|---|
| 00B | 6.4 mm | Ø7.1 mm |
| 0B | 8.3 mm | Ø9.1 mm |
| 1B | 10.6 mm | Ø12.1 mm |
| 2B | 13.6 mm | Ø15.1 mm |
| 3B | 16.6 mm | Ø18.1 mm |
| 4B | 23.6 mm | Ø25.1 mm |
Typical Applications
- Industrial control equipment
- Test and measurement instruments
- Medical and laboratory equipment
- Communication devices
- Automation systems
- Frequently disconnected equipment
- Non-locking panel interfaces
- Indoor electronic equipment
Final contact configuration, keying option, mating connector, panel thickness and termination method should be confirmed according to the selected part number before ordering. Because this version has no locking mechanism, cable routing and equipment design should avoid unintended tensile loads at the mating interface.